5 Repair
5.2.8 Replacing the main computer
Continued
i
Continues on next page
234
Action
For the robot signal exchange proxy:
K2.X8 - A2.X6
(option): K2.X2 - K4.X8, A2.X1
K2.X12 - A2.K3.X6, A2.K3.X7
K2.X10 - A1.X13
K2.X21 - TempSensor (G3.TEMP)
K2.X4 - A1.X9
K2.X3 - K6.X1, A2.K3.X1, K5.1.X4,
K7.X1
K2.X1 - T2.X2
K2.X17 - G3.X1, G1.X2
K2.X6, K2.X11 - A1.X2
K2.X7, K2.X22 - Harn. LV robot
power (X1)
K2.X9 & X13 - FlexPendant (X4)
For the Ethernet extension switch:
K2.X2 - K4.X8, A2.X1
K4.X7 - K5.1.X5
K4.X6 - A2.X4
For the connected services gateway:
i
K7.X1 - K2.X3
K7.X2 - A2.X5
Note
The connector K7.X2 is locked;
grab the connector, push it in to
release it and then remove the
connector.
For the main computer:
A2.X3 - X24
K2.X8 - A2.X6
K2.X2 - K4.X8, A2.X1
K2.X12 - A2.K3.X6, A2.K3.X7
K6.X2 - A2.X9
A2.X5 - K7.X2
A2.X4 - K4.X6/K5.1.X5
Note
If the Ethernet extension switch is
installed, connect and disconnect
the connector A2.X4 to/from
K4.X6.
If the Ethernet extension switch is
not installed, connect and discon-
nect the connector A2.X4 to/from
K5.1.X5.
For Connected Services Gateway wired, there is no power cable.
© Copyright 2020-2021 ABB. All rights reserved.
Note/Illustration
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E