5 Repair
5.2.3.1.1 Replacing the standard fan
Continued
Refitting the standard fan
Refitting the standard fan to the bracket
1
2
Refitting the standard fan
1
2
Continues on next page
190
Action
Refit the standard fan to the bracket.
Tip
Be careful with the locking hole on the
cabinet when doing assembling or disas-
sembling work.
xx1900001498
Secure the screws.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
30.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
43.
© Copyright 2020-2021 ABB. All rights reserved.
Note/Illustration
Screws: Torx pan head screw M4x8 (4 pcs)
xx1900001489
Note/Illustration
Location of wrist strap button:
xx1900001446
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E