3 Installation and commissioning
3.5.5 Connecting power supply to and grounding the controller
Continued
xx1900001455
1
2
3
4
5
PE
Required equipment
Equipment
Main connection cable (single phase)
External earth fault protection (residual current device,
RCD)
Standard toolkit
Circuit diagram
Line fusing
There is no integrated fuse in side OmniCore C90XT controller. An external fuse
or circuit breaker must be added by the integrator, according to the full load current
rating. See
Connecting the power
The following procedure describes how to connect the main power to the controller.
Continues on next page
76
Description
Live (L)
Neutral (N)
Not used
Not used
Not used
Protective Earth, grounding
Line fusing on page
CAUTION
Always inspect the connector for dirt or damage before connecting it to the
controller. Clean or replace any damaged parts.
© Copyright 2020-2021 ABB. All rights reserved.
Note
L, N, PE
Details see
on page
30 mA
See
on page
Circuit diagram - OmniCore
C90XT, 3HAC065464-009
41.
Product manual - OmniCore C90XT
Fitting the connector
72.
Standard toolkit for controller
424.
3HAC073706-001 Revision: E