ABB Robotics OmniCore C90XT Product Manual page 301

Table of Contents

Advertisement

2
3
4
5
Refitting the motor connector
Refitting the motor connector
1
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
Action
Remove the attachment screws on the
cover.
Push the motor connector into the cabin-
et.
Take the motor connector cable out from
the velcro in the cabinet.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
Take the motor connector out.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
30.
© Copyright 2020-2021 ABB. All rights reserved.
5.3.2.1 Replacing the motor connector
Note/Illustration
xx1900001916
Note/Illustration
Continues on next page
5 Repair
Continued
301