5 Repair
5.2.4 Replacing the robot signal exchange proxy
Continued
Removing the robot signal exchange proxy
1
2
3
Continues on next page
200
Action
Disconnect:
K2.X8 - A2.X6
(option): K2.X2 - K4.X8, A2.X1
K2.X12 - A2.K3.X6, A2.K3.X7
K2.X10 - A1.X13
K2.X21 - TempSensor (G3.TEMP)
K2.X4 - A1.X9
K2.X3 - K6.X1, A2.K3.X1, K5.1.X4,
K7.X1
K2.X1 - T2.X2
K2.X17 - G3.X1, G1.X2
K2.X6, K2.X11 - A1.X2
K2.X7, K2.X22 - Harn. LV robot
power (X1)
K2.X9 & X13 - FlexPendant (X4)
Remove the mating connectors by
loosening their attachment screws.
Pull the cable ties out from the locking
holes.