ABB Robotics OmniCore C90XT Product Manual page 326

Table of Contents

Advertisement

5 Repair
5.3.6 Replacing the cable grommet assembly
Continued
6
Refitting the cable grommet assembly
1
2
Continues on next page
326
Action
Refit the cable entry frame to the enclos-
ure wall and secure with the screws.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
30.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
43.
© Copyright 2020-2021 ABB. All rights reserved.
Note/Illustration
Screws: Torx pan head screw M4x8 (4 pcs)
Tightening torque: 1.5 Nm.
xx1900002332
Note/Illustration
Location of wrist strap button:
xx1900001446
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E

Advertisement

Table of Contents
loading

Table of Contents