ABB Robotics OmniCore C90XT Product Manual page 398

Table of Contents

Advertisement

7 Troubleshooting
7.3.6 Troubleshooting the connected services gateway
Continued
Troubleshooting procedure for options 3G or WiFi
The troubleshooting table is supposed to be used as a detailed instruction together
with the troubleshooting flowchart.
1
2
3
4
5
6
Continues on next page
398
Action
Check the STATUS LED on the Connec-
ted Services Gateway.
Check the LINK LED on the Connected
Services Gateway.
Measure the input voltage to the Connec-
ted Services Gateway.
Check that the connector X2 is well con-
nected and the network connection prop-
erties are available.
Check the indicator RF LEDs on the
Connected Services Gateway.
Check that the connector X3 is well con-
nected.
© Copyright 2020-2021 ABB. All rights reserved.
Note
If the LED is:
Red/green, flashing: An internal
error has occurred, proceed with
step 11.
OFF, the unit is faulty, or it does
not have sufficient input voltage,
or the connection of the connector
X2 is not ok. Proceed with step 3.
If the LED is:
OFF, the unit is faulty, or it does
not have sufficient input voltage,
or the connection of the connector
X2 is not ok. Proceed with step 3.
Flashing: An internal error has oc-
curred, proceed with step 11.
Use a multimeter and insulating gloves.
The input voltage should be 24 V.
Make sure that connector X1 is connected
properly on both ends.
If the input voltage is normal, pro-
ceed with step 4.
If the input voltage is abnormal,
Troubleshooting the robot signal
exchange proxy on page
Tip
For more details, see Circuit dia-
gram - OmniCore C90XT.
Make sure that connector X2 is connected
properly on both ends.
If the connection is OK, proceed
with step 5.
If there is a problem with the con-
nection, repair the connection and
go back to step 1.
If the RF LEDs are:
ON, the Connected Services Gate-
way is connected to network and
works well.
OFF, the Connected Services
Gateway is faulty or the connection
of the connector X3 is not ok. Pro-
ceed with step 6.
Make sure that connector X3 is connected
properly on both ends.
If the connection is OK, proceed
with step 7.
If there is a problem with the con-
nection, repair the connection and
go back to step 5.
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
414.

Advertisement

Table of Contents
loading