ABB Robotics OmniCore C90XT Product Manual page 312

Table of Contents

Advertisement

5 Repair
5.3.4 Replacing the power inlet
Continued
3
4
5
6
Concluding procedure
1
2
312
Action
Insert the power inlet into the cover of
the cabinet.
Secure it with the screws.
Reconnect:
X0 - Q0.
X0 - A1.X1.
PE.3 & PE.4.
Reconnect the mains switch to the
handle for 6 switch.
Action
Close the door.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
171.
© Copyright 2020-2021 ABB. All rights reserved.
Note/Illustration
Screws: Torx pan head screw M4x8 (4 pcs)
xx1900001918
xx1900001920
Note/Illustration
Closing the door on page
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
180.