3 Installation and commissioning
3.5.9 Descriptions for connectors
Continued
Conveyor tracking module
For detail information on customer connections to conveyor tracking module, see
Application manual - Conveyor tracking, 3HAC066561-001.
xx1800000941
Customer cable layout
It is recommended to use multicore cable for the customer connection.
The cables connected by customer to the conveyor tracking module should go
through the cable grommet and fasten on the cabinet.
Continues on next page
92
Note
The end user need to buy proper grommets according to the diameter of the
cables which need to go through the grommet.
This will affect the protection level of the cabinet if it's not executed correctly.
It is recommended to use icotek KT grommet.