Troubleshooting flowchart
xx1800001831
Detailed working procedure
1
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
Problem starting or
connecting the FlexPendant
Check connector X4
Check LEDs:
HMI & PC
Check FlexPendant
cable
Check connection
K2.X9 to X4
Check:
K2.X8 - A2.X6
K2.X2 - A2.X1
K2.X12 - A2.K3.X6,7
K2.X3 - A2.K3.X1
Replace FlexPendant
Not starting
Start FlexPendant
Problem solved
Action
Try resetting the FlexPendant using the reset
button located next to the USB port.
© Copyright 2020-2021 ABB. All rights reserved.
7.2.5 Problem starting or connecting the FlexPendant
Connection not ok
Connection ok
Not lit
Green
Cable
damaged
Cable ok
Connection
not ok
Connection
not ok
Connections ok
Ok
7 Troubleshooting
Continued
Repair connection
Troubleshoot robot signal
exchange proxy K2
Replace FlexPendant
cable
Note
See Operating manual - OmniCore.
Continues on next page