3 Installation and commissioning
3.7.4 Installing the power supply optional device
Continued
2
3
Concluding procedure
1
2
124
Action
Refit the end clamp besides the power
supply.
Connect:
T5.X1-AC Terminal block
T5.X2-24V Terminal block
Note
The connector on the AC_in cable
(3HAC061099-001) is fastened to the
cable clip in the illustration when the
power supply optional is not selected.
Action
Close the door.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
171.
© Copyright 2020-2021 ABB. All rights reserved.
Note/Illustration
For DSQC 609:
xx1900001907
For DSQC 634:
xx1900002443
Note/Illustration
Closing the door on page
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E