ABB Robotics OmniCore C90XT Product Manual page 368

Table of Contents

Advertisement

7 Troubleshooting
7.2.2 Start-up failure
Continued
Troubleshooting flowchart
xx1800001829
Detailed working procedure
1
2
3
Continues on next page
368
Start-up failure
Red or flashing
Check LED AC
Green
Not lit
Check LED PS
Green
Not lit
Check LEDs:
MS, PC, HMI
Green
Check LEDs:
Not lit
PC PWR, PC HDD,
PC STAT
Lit
Problem solved
Action
Look at the LED AC.
Look at the LED PS.
Look at the LED MS.
© Copyright 2020-2021 ABB. All rights reserved.
Yes
No
CRB 15000 controller
Note
LED AC should be green.
LED PS should be green.
For more details about the LEDs,
see
Troubleshooting the robot sig-
nal exchange proxy on page
LED MS should be green.
Product manual - OmniCore C90XT
Troubleshoot power
unit A1
Troubleshoot power
supply T2
Troubleshoot robot
signal exchange
proxy K2
Troubleshoot main
computer
If not, see
Troubleshooting
the power unit on page
388.
If the power unit is ok, check
that the power inlet is well
connected and the power
inlet switch is turned on.
If not, see
Troubleshooting
the power supply on
page
407.
If the power supply is ok,
see
Troubleshooting the
power unit on page
388.
If the power unit is ok, check
that the power inlet is prop-
erly connected and the
power inlet switch is turned
on.
414.
If not, see
Troubleshooting
the robot signal exchange
proxy on page
414.
3HAC073706-001 Revision: E