3 Installation and commissioning

3.5.8 Set up the network connection

3.5.8 Set up the network connection
Management port
The management port is intended for service engineers and programmers
connecting directly to the controller with a PC.
The management port is configured with the fixed IP address 192.168.125.1, which
is the same for all controllers and cannot be changed, and has a DHCP server that
automatically assigns an IP address to the connected PC.
WAN port
The WAN port is a public network interface to the controller, typically connected
to the factory network with a public IP address provided by the network
administrator.
The WAN port can be configured with fixed IP address, or DHCP, from RobotStudio
or the FlexPendant. By default the IP address is blank.
Continues on next page
86
Note
Do not connect another DHCP server to this port.
Note
For more information about connecting a PC to the management port, see section
Working online in Operating manual - RobotStudio.
Note
It is not recommended using leading zeros in dot-decimal notation of IP
addresses. The numbers may wrongly be interpreted as octal numbers. Different
behaviors on virtual and real controllers may be experienced.
Note
The WAN port cannot use any of the following IP addresses which are allocated
for other functions on the controller:
192.168.125.0 - 255
192.168.126.0 - 255
192.168.127.0 - 255
The WAN port cannot be on a subnet which overlaps with any of the above
reserved IP addresses. If a subnet mask in the class B range has to be used,
then a private address of class B must be used to avoid any overlapping. Contact
your local network administrator regarding network overlapping.
See the section Communication in Technical reference manual - System
parameters.
© Copyright 2020-2021 ABB. All rights reserved.
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E