ABB Robotics OmniCore C90XT Product Manual page 340

Table of Contents

Advertisement

5 Repair
5.3.8 Replacing the harness ETH outlet with cable
Continued
3
4
5
6
7
Refitting the harness ETH outlet with cable
Refitting the harness ETH outlet with cable
1
2
3
Continues on next page
340
Action
Remove the attachment screws on the
door.
Push the harness ETH outlet with cable
into the cabinet.
Disconnect:
X24 - A2.X3
Remove the cables out from the clips in
the cabinet carefully.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
Take the harness ETH outlet with cable
out from the upper side.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
30.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
43.
Insert the harness ETH outlet with cable
into the cover from inner side of the
cabinet.
© Copyright 2020-2021 ABB. All rights reserved.
Note/Illustration
xx1900001924
Note/Illustration
Product manual - OmniCore C90XT