Restoring the hardware settings
The controller hardware settings include information such as controller type and
serial number. When the main computer has been replaced, the serial number
must be restored before any software can be installed, or any licences can be
imported.
1
2
3
4
5
6
7
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
Note
When replacing the main computer, both the serial number and licences are lost.
The serial number must be restored as described below. Licences however, can
either be restored automatically when the RobotWare system is installed, or
manually through Manage Licences in RobotWare Installation Utilities.
Action
Download the hardware information file
(hwsettings.rsf) from MyABB, or from a
previous system backup.
Access the RobotWare Installation Utilit-
ies.
Tap Advanced, and then Restore Hard-
ware Settings.
The Restore Hardware Settings window
is displayed.
Follow the instructions and tap Next to
proceed.
Carefully read the information and then
check all boxes to confirm that you agree
with the ABB conditions. Tap Next to
proceed.
Read the serial number on the front of
the controller and type it in field Serial
Number. Tap Next.
Tap Browse to open the hardware inform-
ation file from its location. The restoration
of the serial number is completed.
© Copyright 2020-2021 ABB. All rights reserved.
5.2.8 Replacing the main computer
Note/Illustration
xx1900000110
xx2000000007
The system compares the downloaded file
and the manually entered serial number to
ensure that there is a match.