3 Installation and commissioning
3.8.2 Installing the conveyor tracking module to extension box
Continued
5
6
7
8
9
For more information about the option Conveyor Tracking, see Application
manual - Conveyor tracking.
158
Action
Connect the 24V power supply to the
conveyor tracking module from the basic
box or other power supply.
Connected to Ethernet through the cable
grommet:
B1.X7 - K4.X1-5
Connect wires to the input and output
connectors as required.
Close the door.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
171.
© Copyright 2020-2021 ABB. All rights reserved.
Note/Illustration
How to insert cable through cable grommet,
see
Releasing the cables from the cable
grommet assembly on page 321
the cables to the cable grommet assembly
on page
324.
For details on connecting wires to the con-
veyor tracking module, see Application
manual - Conveyor tracking.
Closing the door on page
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
and
Refitting
180.