ABB Robotics OmniCore C90XT Product Manual page 212

Table of Contents

Advertisement

5 Repair
5.2.6 Replacing the connected services gateway
Continued
2
3
4
i
Reconnecting the antenna
1
2
Continues on next page
212
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
43.
Hook up the connected services gateway
to the bracket and push carefully into
position.
Note
During the installation, the gap between
the lower surface of the connected ser-
vices gateway and the upper surface of
the main computer should be zero.
Reconnect:
i
K7.X1 - K2.X3
K7.X2 - A2.X5
For connected services gateway wired, there is no power cable.
Action
Insert the cable from the cable grommet.
Refit the cable in the cabinet according
to the record during the disassembly.
© Copyright 2020-2021 ABB. All rights reserved.
Note/Illustration
xx1900002331
Note/Illustration
Refitting the cable grommet assembly on
page
324.