Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
43.
Hook up the Ethernet extension switch
to the bracket and then push the switch
into position.
Note
During the installation, there should be
no gap between the upper surface of the
Ethernet extension switch and the lower
surface of highest bracket on the main
computer.
xx1800000972
Reconnect:
K2.X2 - K4.X8, A2.X1
K4.X7 - K5.1.X5
K4.X6 - A2.X4
Action
Close the door.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
171.
© Copyright 2020-2021 ABB. All rights reserved.
5.2.5 Replacing the Ethernet switch
Note/Illustration
Location of wrist strap button:
xx1900001446
xx1900002330
Note/Illustration
Closing the door on page
5 Repair
Continued
180.