ABB Robotics OmniCore C90XT Product Manual page 408

Table of Contents

Advertisement

7 Troubleshooting
7.3.10 Troubleshooting the power supply
Continued
A
Description
DC OK LED
Required test equipment
Equipment needed for troubleshooting.
Equipment
Multimeter
Insulating gloves
Circuit diagram - OmniCore C90XT
Preparations
1
2
3
Continues on next page
408
DC OK LED
Significance
Green: All DC outputs are above the specified minimum levels.
Off: One or more DC outputs are below the specified minimum level.
Action
Check the FlexPendant for errors and warnings.
Power the controller off. Wait one minute, power the controller on.
Wait 30-60 seconds after power-on.
Make sure that the control system power is in run-time mode.