3 Installation and commissioning
3.8.1 Installing the extension box
Continued
Specifications
It is recommended to use multicore cable for the customer connection.
The following describes the cable requirements for the X106 connection in the
extension box.
Component
Cable type
Cable area
Included parts
The following parts are included in the delivery when the extension box is selected.
Part
Connector for X106
Procedure
Use this procedure to stack an extension box to a basic box.
1
2
3
Continues on next page
152
Description
Flexible oil resistant rubber
4C x 0.5 mm
Action
Place the controller in desired place.
Fix the basic box to a concrete foundation
or steel platform with anchor bolts.
Remove the four plastic screw.
© Copyright 2020-2021 ABB. All rights reserved.
2
or AWG20
Order number
3HAC074661-001
Info/illustration
Anchor bolts: M8 X 4
Tighten torque: 11.3 Nm-12.6 Nm
xx1900001450
Product manual - OmniCore C90XT
Quantity
1
3HAC073706-001 Revision: E

Advertisement