ABB Robotics OmniCore C90XT Product Manual page 122

Table of Contents

Advertisement

3 Installation and commissioning
3.7.4 Installing the power supply optional device
Continued
Required documents
Document
Circuit diagram - OmniCore C90XT
Installing the optional power supply
Preparations
1
2
3
Installing the 24V terminal block
1
Continues on next page
122
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
30.
Open the door.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
43.
Action
Hang the 24V terminal block to the
bracket and push the lower part until you
hear a clear clicking sound.
© Copyright 2020-2021 ABB. All rights reserved.
Article number
Note
3HAC065464-009
Note/Illustration
Opening the door on page
Location of wrist strap button:
xx1900001446
Note/Illustration
Product manual - OmniCore C90XT
180.
3HAC073706-001 Revision: E