Overview
A fan/battery module is always required for cooling the SIMOTION D4x5-2 Control Unit.
Table 4- 8
Fan/battery module for SIMOTION D4x5-2
Property
Fan/battery module
Fan/battery module included
in the D4x5-2 scope of
delivery
Usable fan/battery modules
Max. permissible supply air
temperature
Fan control
The fan/battery modules are usually supplied with a backup battery.
Fan faults
Fan faults are indicated as follows:
● Entry in diagnostics buffer
● In the event of fan failure (both fans in the double fan/battery module failed) the RDY LED
● Indicated via system variable
● Call to the PeripheralFaultTask
For further information on the evaluation of fan faults, see Section Overview of the
fan/battery module states (Page 108).
106
SIMOTION D425-2 DP
SIMOTION D425-2 DP/PN
Always required (double
fan/battery module included
in the D425-2's scope of
delivery)
Double fan/battery module
6FC5348-0AA02-0AA0
Only type
6FC5348-0AA02-0AA0
(double fan)
55° C
Temperature-controlled fan unit will be switched on depending on supply air temperature
and CPU load
flashes red/yellow at 2 Hz
SIMOTION D435-2 DP
SIMOTION D435-2 DP/PN
Always required (double
fan/battery module included
in the D435-2's scope of
delivery)
Double fan/battery module
6FC5348-0AA02-0AA0
Only type
6FC5348-0AA02-0AA0
(double fan)
55℃
Commissioning and Hardware Installation Manual, 02/2012
SIMOTION D445-2 DP/PN
SIMOTION D455-2 DP/PN
Always required (double
fan/battery module included
in the scope of delivery
of the D445-2 DP/PN and
D455-2 DP/PN)
Double fan/battery module
6FC5348-0AA02-0AA0
Only type
6FC5348-0AA02-0AA0
(double fan)
55° C