Clock Datetime - H3C S5120-SI Series Command Reference Manual

Hide thumbs Also See for S5120-SI Series:
Table of Contents

Advertisement

1
Basic Configuration Commands
Basic Configuration Commands

clock datetime

Syntax
clock datetime time date
View
User view
Default Level
3: Manage level
Parameters
time: Configured time, in the format of HH:MM:SS, where HH is hours in the range 00 to 23, MM is
minutes in the range 00 to 59, and SS is seconds in the range 00 to 59. The first zero in the HH, MM, or
SS value can be omitted; if the value of SS is 00, the time argument can be represented in the format of
HH:MM; if both the values of MM and SS are 00s, the time argument can be represented in the format
of HH.
date: Configured date, in the format of MM/DD/YYYY or YYYY/MM/DD. MM is the month of the year in
the range 1 to 12, DD is the day of the month that varies with months, and YYYY is a year in the range
2000 to 2035.
Description
Use the clock datetime command to set the current time and date of the device.
The current time and date of the device must be set in an environment that requires the acquisition of
absolute time.
You may choose not to provide seconds when inputting the time parameters.
Related commands: clock summer-time one-off, clock summer-time repeating, clock timezone,
display clock.
Examples
# Set the current system time to 14:10:20 08/01/2005.
<Sysname> clock datetime 14:10:20 8/1/2005
# Set the current system time to 00:06:00 01/01/2007.
<Sysname> clock datetime 0:6 2007/1/1