Default Level
2: System level
Parameters
channel-number: Specifies a channel number, in the range 0 to 9.
channel-name: Specifies a channel name, which could be a default name or a self-defined name. The
user needs to specify a channel name first before using it as a self-defined channel name. For more
information, refer to the info-center channel name command.
Description
Use the info-center console channel command to specify the channel to output system information to
the console.
Use the undo info-center console channel command to restore the default output channel to the
console.
By default, output of information to the console is enabled with channel 0 as the default channel (known
as console).
Note that the info-center console channel command takes effect only after the information center is
enabled first with the info-center enable command.
Examples
# Set channel 0 to output system information to the console.
<Sysname> system-view
[Sysname] info-center console channel 0

info-center enable

Syntax
info-center enable
undo info-center enable
View
System view
Default Level
2: System level
Parameters
None
Description
Use the info-center enable command to enable information center.
Use the undo info-center enable command to disable the information center.
The system outputs information to the log host or the console only after the information center is
enabled first.