Reset Unused Porttag - H3C S5120-SI Series Command Reference Manual

Hide thumbs Also See for S5120-SI Series:
Table of Contents

Advertisement

Device reboot may result in the interruption of the ongoing services. Use these commands with
caution.
If a main boot file fails or does not exist, the device cannot be rebooted with the reboot command.
In this case, you can re-specify a main boot file to reboot the device, or you can power off the
device, then power it on and the system automatically uses the backup boot file to restart the
device.
If you are performing file operations when the device is to be rebooted, the system does not
execute the command for the sake of security.
Examples
# If the current configuration does not change, reboot the device.
<Sysname> reboot
Start to check configuration with next startup configuration file, please wait.........DONE!
This command will reboot the device. Continue? [Y/N]:y
Now rebooting, please wait...
# If the current configuration changes, reboot the device.
<Sysname> reboot
Start to check configuration with next startup configuration file, please wait.........DONE!
This command will reboot the device. Current configuration will be lost in next startup if
you continue. Continue? [Y/N]:y
Now rebooting, please wait...

reset unused porttag

Syntax
reset unused porttag
View
User view
Default Level
1: Monitor level
Parameters
None
Description
Use the reset unused porttag command to clear the 16-bit index saved but not used in the current
system.
Examples
# Clear the 16-bit index saved but not used in the current system.