1

RMON Configuration Commands

RMON Configuration Commands
display rmon alarm
Syntax
display rmon alarm [ entry-number ]
View
Any view
Default Level
1: Monitor level
Parameters
entry-number: Index of an RMON alarm entry, in the range 1 to 65535. If no entry is specified, the
configuration of all alarm entries is displayed.
Description
Use the display rmon alarm command to display the configuration of the specified or all RMON alarm
entries.
Related commands: rmon alarm.
Examples
# Display the configuration of all RMON alarm table entries.
<Sysname> display rmon alarm
AlarmEntry 1 owned by user1 is VALID.
Samples type
Variable formula
Sampling interval
Rising threshold
Falling threshold
When startup enables
Latest value
Table 1-1 display rmon alarm command output description
AlarmEntry entry-number owned by
owner is status
: absolute
: 1.3.6.1.2.1.16.1.1.1.4.1<etherStatsOctets.1>
: 10(sec)
: 50(linked with event 1)
: 5(linked with event 2)
: risingOrFallingAlarm
: 0
Field
Description
The status of the alarm entry entry-number created by
the owner is status.
entry-number: Alarm entry, corresponding to the
management
information
alarmIndex.
1-1