Continuity check
Graphic
Fig. 1
2.1)

Controller boards on the FUSE BOX

See
The EMS grounding cables of the wiring harness (labelled: "Regulator A"
or cables with cable lugs) must be connected to the 3 attachment points of
the EMS ground. Each side of the FUSE BOX has three ground connec-
tions.
EMS ground has 3 interconnected ground connections which may be used
interchangeably.
Airframe ground, also has 3 interconnected ground connections which
may be used interchangeably, one of which must be connected to the air-
frame ground.
NOTE:
Effectivity: 912 i Series
Edition 1/Rev. 2
BRP-Powertrain
INSTALLATION MANUAL
1
Part
1
Multimeter
2
Rectifier regulator A (black wire connector)
3
Rectifier regulator B (grey wire connector)
Fig. 2
and
Fig. 3.
Airframe ground is independent of EMS ground and must
NOT be interconnected.
The tightening torque of the nuts to secure the EMS
NOTICE
WARNUNG
grounding cables and the airframe ground of the re-
spective attachment points must be 1.2 Nm
(10.7 in.lb).
2
Function
3
24-00-00