S2600E CLI Reference Guide
Usage
guidelines
Examples
Related
commands
15.5.5
icmp-guard
monitored-host-limit
Use this command to set the maxmum monitored host number.
icmp-guard monitored-host-limit number
Parameter
description
Default
Settings
Command
mode
Chapter 15 NFPP Configuration Commands
When the attacker is detected, if the isolate period is
0, the attacker will be monitored by the software and the
timeout time will be the monitor period. During the
software monitoring, if the isolate period is not 0, the
software-monitored attacker will be auto-isolated by the
hardware and the timeout time will be the isolate period.
The monitor period is valid with the isolate period 0.
If the isolate period has changed to be 0, the
attackers on the interface will be removed rather than
being monitored by the software.
Ruijie(config)# nfpp
Ruijie(config-nfpp)# icmp-guard monitor-period 180
Command
show nfpp
icmp-guard summary
show nfpp
icmp-guard hosts
clear nfpp icmp-guard
hosts
Parameter
Description
number
The
number.
1-4294967295.
1000
NFPP configuration mode
Description
Show the configurations.
Show the monitored host list.
Clear the isolated host.
maximum
monitored
The
valid
range
host
is