S2600E CLI Reference Guide
Related
commands
7.1.16
Use this command to attach sequential numbers into the logs. The no format of
the command removes the sequential numbers in the logs.
service sequence-numbers
no service sequence-numbers
Parameter
description
Default
configuration
Command
mode
Usage
guidelines
Examples
Related
commands
7.1.17
Use this command to attach system name to logs. The no format of the
command removes the system name from the logs.
service sysname
no service sysname
Chapter 7 Syslog Configuration Commands
Command
logging file flash
service sequence-numbers
N/A.
No sequential numbers are attached.
Global configuration mode.
In addition to the timestamp, it is possible to add
sequential numbers to the logs, numbering from 1. Then, it
is clearly known whether the logs are lost or not and their
sequence.
The example below adds sequential numbers to the logs.
Ruijie(config)# service sequence-numbers
Command
logging on
service
timestamps
service sysname
Function
Record the logs to the FLASH.
Description
Record logs on different devices.
Attach the timestamp to the logs
Need help?
Do you have a question about the RG-S2600E Series and is the answer not in the manual?