S2600E CLI Reference Guide
6.1.4
diagnostic monitor active
Use this command to set the health monitoring test status for a test item of a
particular management board or slot in global configuration mode: active or
inactive.
diagnostic monitor active [slot slot_id [sub_system subsys_id]] test {all |
test-id | range test-range}
no diagnostic monitor active [slot slot_id [sub_system subsys_id]] test
{all | test-id | range test-range}
Parameter
description
Default
Command
mode
Usage
guidelines
Examples
Chapter 6 GRTD Configuration Commands
Parameter
Description
slot slot_id
Slot ID
(Optional) Subsystem ID (value range: 0-1), whose
sub_system
meaning is equivalent to cpu id in the show version
subsys_id
command.
test{all
|
test-id
|
Test items. all means all items; range means a
range
range, for example, from item m to item n.
test-range}
Active
Global configuration mode
Use the diagnostic monitor active command to set the health
monitoring test status for a test item of a particular management
board or slot.
You can set the health monitoring test status for a test item of a
particular management board or slot to active or inactive.
The health monitoring test status for a
destructive test cannot be set to active. You
can view the attributes of test items of slots or
management boards by using the show
Caution
diagnostic content command.
Example 1: The following example sets the health monitoring test