14. TONER COLLECTION SECTION

14.3 Operation

14.3.1

Toner collection control

Toner collection section is driven by the transfer belt motor (M18) and the paper feed motor (M41).
Collecting toner is performed by the M18 that drives the transfer belt and the paper feed operation driven
by the M41.
14.3.2

Toner collection box control

The presence of toner collection box is detected by on/off of the waste toner door sensor (PS60).
14.3.3

Box full control

When the waste toner full sensor (PS52) is turned on, a warning message is displayed on the touch panel.
There is a box full counter in the NVRAM board (NRB). After the PS 52 is turned on, the counter starts
counting.
For operation details, refer to the table blow.
PS60
PS52
ON
OFF
ON
ON
ON
ON
64
Box full counter
Less than 2500
2500 or more
Theory of Operation Ver1.0 Sep.2006
Operation
Print available
• Warning message is displayed on the touch panel when
the PS52 turns on.
• After the PS52 turns on, printing is available unless the
count exceeds 2500.
• Rejects incoming new jobs
• Job in progress is continued 3000 is counted.
• Print stopped at 3000 counts