Theory of Operation Ver1.0 Sep.2006
10.2 Operation
10.2.1
Charging control
A. Charging wire
•
The high voltage unit /1 (HV/1) boosts 24 VDC and apply a negative DC voltage to the charging wire. The
wire discharges the negative voltage.
•
Charging output range: -450 to -1,100 µA
B. Charging grid
•
To let the charging wire discharge stably, a negative high voltage is applied to the charging grid from the
high voltage unit /1 (HV/1).
•
Charging grid output range: -250 to -1,000V
10. CHARGING SECTION
47
Need help?
Do you have a question about the ineo+ 6500 and is the answer not in the manual?
Questions and answers