4. PAPER FEED SECTION
4.3.2

Original size detection

Original size detection signal is detected by scanning in the main direction and sub direction.
The original size detection method differs between normal copy mode and mixed original copy mode.
A. Normal copy mode
Main scan direction is detected by the resistance value of the size VR (VR301) interlocked with the guide
plate position on the paper feed tray
Sub-scanning direction is detected by the combination of the size sensor/S (PS309) and size sensor/L
(PS310) when they are turned on and off.
B. Mixed original copy mode
Maximum original size in main scan direction is detected by the resistance value of the size VR (VR301)
interlocked with the guide plate position on the paper feed tray.
Sub scan direction is detected by the time when the original passes by the timing sensor (PS302).
Allowed size combinations are as shown in the table below.
For metric area
Other
originals
A3
A3
A4
B4
Thick
paper
B5
A4S
Thick
paper
A5
B5S
A5S
*1
B6S
*2
12
Standard originals (max. original size detected by guide plate)
A4
B4
B5
Thick
paper
Thick
Thick
Thick
paper
paper
paper
*1
*2
Theory of Operation Ver1.0 Sep.2006
A4S
A5
B5S
Thick
Thick
paper
paper
A5S
B6S