25. OTHER CONTROLS
I.
Power supply fan (M42) control
(1) Purpose
To cool the DC power unit /1 (DCPS/1), /2 (DCPS/2).
(2) Low/high speed switching timing
Rotates at low speed during standby.
Switches to high speed upon starting of printing.
Switches to low speed a predetermine time period after printing is finished.
J.
Writing suction fan /1 (M43), /2 (M44) control
(1) Purpose
To cool the polygon motor and the writing optical parts.
(2) ON timing
Rotates at high speed during standby and printing.
The number of revolutions during standby can be set using software DIPSW.
K. Developing fan /1 (M45), /2 (M46), /3 (M64) control
(1) Purpose
To cool around the developing section.
(2) ON timing
Starts to operate upon starting of the developing motor /Y (M14), developing motor /M (M15), developing
motor /C (M16) and developing motor /K (M17).
(3) OFF timing
Stops a predetermined time period after printing is finished.
The predetermined time period differs depending on the ambient humidity. (5 minutes 30 seconds at max.)
L.
Main unit fan (M47) control
(1) Purpose
To cool around the drum section.
(2) ON timing
Starts to operate upon starting of the developing motor /Y (M14), developing motor /M (M15), developing
motor /C (M16) and developing motor /K (M17).
(3) OFF timing
Stops a predetermined time period after printing is finished.
The predetermined time period differs depending on the ambient humidity. (5 minutes 30 seconds at max.)