21. FUSING SECTION
21.3.5

Fusing roller/Lw cooling control

When the temperature of the fusing roller /Lw [2] detected by the temperature sensor /2 (TEMS/2) rises
higher than a specified temperature, and the difference between the detected and the specified tempera-
tures exceeds a predetermined level, the fusing fan /Lw (M65) [4] turns on and cools down the fusing roller
/Lw.
While the M65 is operating, the fusing heater lamp /4 is kept off.
The fusing fan /Lw (M65) takes in air from the front side, through the duct [3] to cool the fusing roller /Lw.
Air that passed through the fusing roller /Lw is exhausted to the rear side through the duct [1].
[4]
[1]
Duct
[2]
Fusing roller /Lw
108
[3]
[3]
Duct
[4]
M65
Theory of Operation Ver1.0 Sep.2006
[1]
[2]
a03ut2c083ca