Theory of Operation Ver1.0 Sep.2006
M. Charging air suction fan (M48) control
(1) Purpose
•
To cool around the charging coronas.
(2) ON timing
•
Starts to operate upon starting of charging.
•
Starts to operate upon starting of image stabilization control.
(3) OFF timing
•
Stops a predetermined time period after printing is finished.
•
Stops a predetermined time period after finishing the image stabilization control.
N. Paper exit fan /1 (M61), /2 (M62), /3 (M63) control
(1) Purpose
•
To cool the exited paper to prevent unevenness of wax on the paper surface.
(2) ON timing
•
Starts to operate upon starting of printing.
(3) OFF timing
•
FS connected : Stops a predetermined time period after the FS paper exit sensor turns off.
•
FS disconnected: Stops a predetermined time period after the main unit paper exit sensor (PS13) turns off.
O. Fusing fan/Lw (M65) control
(1) Purpose
•
To cool the fusing roller /Lw.
(2) ON timing
•
Starts to operate when the temperature of the fusing roller /Lw rises higher than a prescribed level exceed-
ing the allowable range.
•
The M65 and the fusing heater lamp /4 (L5) do not turn ON at the same time.
(3) OFF timing
•
Stops when the temperature of the fusing roller /Lw drops to a prescribed level.
P.
ADU fan /1 (M66) control
(1) Purpose
•
To cool around the ADU.
(2) ON timing
•
Starts to operate upon starting of printing in double side or reverse paper exit mode.
(3) OFF timing
•
Stops a predetermined time period after printing is finished.
25. OTHER CONTROLS
127