Theory of Operation Ver1.0 Sep.2006
(2) The reading operation when the start button is turned on
•
After finishing the movement for the shading correction, the exposure unit shifts to scanning operation auto-
matically.
•
The other movements of the exposure unit are the same as when the SW2 is turned on.
C. Original reading mode
•
There are two original reading modes; platen mode and DF mode.
•
Whether the density setting is set to manual or AE, the two modes differ in movement of the exposure unit.
(1) When selecting the manual density setting
[1]
[2]
[4]
[5]
[6]
[7]
[1]
Home position
[2]
Scanner home sensor (PS1)
[3]
Platen APS position
[4]
White correction (First time)
[3]
[5]
White correction (Second time)
[6]
Exposure scan
[7]
Home position search
7. SCANNER SECTION
a03ut2c018ca
25
Need help?
Do you have a question about the ineo+ 6500 and is the answer not in the manual?
Questions and answers