Acura Integra 1998 Service Manual page 589

Integra 1998
Hide thumbs Also See for Integra 1998:
Table of Contents

Advertisement

17. Make sure the transmission is in E] position.
Fill the transmission with ATF, and run the engine
Jor 30 seconds or until approximately one quart is
discharged.
'18.
Remove the drain hose, and reconnect the cooler
return hose to the transmission.
19. Refillthe tiansmission with ATF to the propef level.
FILLER CAP
T O O L M A I N T E N A N C E
1. Empty and rinse after each use. Fill the can with
water and pressurize the can. Flush the discharge
line to ensure that the unit is clean.
2.
lf discharge liquid does not foam, the orifice may be
blocked.
3, To clean, disconnect the plumbing from the tank at
the large coupling nut,
4.
Remove the in-line filter trom the discharge side and
clean if necessary.
5. The fluid oritice is located behind the filter.
Clean it with the pick stored in the bottom of the tank
handle or blow it clean with air. Securely reassem-
ble all parts.
COUPLING NUT
FILTER
\
I
O-RING
ORIFICE
14-173