Acura Integra 1998 Service Manual page 1016

Integra 1998
Hide thumbs Also See for Integra 1998:
Table of Contents

Advertisement

lli
''
l t
Recirculation Control Motor
Test
1 .
Connect battery power to the No. 1 terminal of the
recirculation control motor, and connect ground to
the No. 2 and No. 4 terminals; the recirculation con-
trol motor should run smoothly.
Disconnect the No. 2 or No. 4 terminal from ground;
the recirculation control motor should stop at FRESH
o r R E C I R C U L A T E .
CAUTION: Never connect the battery in the oppo-
site dilection.
NOTE: Don't cycle the recirculation control motor
for a long time.
lf the recirculation control motor does not run in step
1, remove it, and check the recirculation control link-
age and door lor smooth movement. If the recircu-
lation control linkage and door move smoothly,
reDlace the recirculation control motor.
3 .
1 . Disconnect the 4P connector from the recirculation
control motor, and remove the wire harness clip from
i t .
2. Remove the two screws, the recirculation
motor and the flange collaf.
scREws
RECIRCULATION
CONTROL MOTOB
lnstall in the revefse order of removal. After instal-
lation, make sure the recirculation control motor runs
smoothly.
4P CONNECTOR
Replacement
21-29