Acura Integra 1998 Service Manual page 388

Integra 1998
Hide thumbs Also See for Integra 1998:
Table of Contents

Advertisement

| '
I
Mainshaft Assembly
Glearance Inspection
N O T E : l f r e p l a c e m e n t i s r e q u i r e d , a l w a y s r e p l a c e t h e
svnchro sleeve and the svnchro hub as a set.
'L
Measure the clearance between 2nd and 3rd qears.
Standard:
0.05 - 0.21 mm (0.002 - 0.C08 in)
Service Limit: 0.3 mm 10,01 inl
13-22
Engine Type
8 1 8 C 1 . 8 1 8 C 5
8 1 8 B 1
Standard
34.92 - 34.97 mm
{ l . 3 7 5 - 1 . 3 7 7 i n )
34.42 - 34.47 mm
( 1 . 3 5 5 - 1 . 3 5 7 i n )
Service Limit
34.8 mm
( 1 . 3 7 0 i n )
34.3 mm
( 1 . 3 5 0 i n )
2.
It the clearance is more than the service limit, mea-
sure the thickness of 3rd gear.
li the thickness of 3rd gear is less than the ser-
vice limit, replace 3rd gear with a new one.
lf the thickness of 3rd gear is within the service
limit, replace the 3rd/4th synchro hub with a new
o n e .
3RD GEAR