Engine Control Module (ECM) Reset Procedure
Either of the following actions will reset the ECM.
.
U s e t h e O B D l l s c a n t o o l o r H o n d a P G M T e s t e r t o c l e a r t h e E C M ' S m e m o r y .
NOTE: See the OBD ll scan tool or Honda PGM Tester use's manuals for specific operating instructions.
. Turn the ignition switch OFF. Remove the BACK UP (RADIO) (7.5 AI tuse from the under hood fuse/relay box for 10
seconds.
BACK UP (RAOIO) {7.5 AI FUSE
UNDER'HOOD
FUSE/RELAY BOX
lll. Final Procedure (this procedure must be done after any trou bleshooting )
1. Remove the SCS Service Connector if it is connected.
NOTE: lf the SCS service connectors is connected and there are no DTCS stored in the ECM, the MIL will stav on
when the ignition switch is turned ON (ll).
2. Do the ECM Reset Procedure.
3. Turn the ignition switch OFF.
4. Disconnect the OBD ll scan tool or Honda PGM Tester from the Data Link Connector (16P|.
{cont'd)