Troubleshooting
Condenser Fan
0
Remove the condenser fan relay
from the underhood fuse/relay
box, and test it (see page 22-19).
Roplaco the condenser fan rgley.
Measure the voltage between tlie
N o . 2 t e r m i n a l { + ) a n d b o d y
ground (-).
Connect the No. 1 and No. 2 ter-
minals with a jumper wire.
Does the condenser fan run?
Check for continuity in the BLU/
BLK wire between lhe No. 1 ter'
minal and the condenser fan.
Ropair open in the BLU/BLK wir.
between tho undor-hood fu3e/
relay box and lh€ condan3er fan.
ls there continuity?
Check for continuity in the BLK
wire between the condenser fan
and body ground.
Check tor an ooen in the BLK
wir6 betwoen the condan3er fan
and body ground. lf the wire is
OK, check for poor ground at
G r 5 1 .
ReDlace the condenser fan motor,
CONDENSER FAN RELAY 4P S(rcKET
ls the relay OK?
YES
RoDlace the undor-hood tuse/
r€lay box.
JUMPER
WIRE
To page 22 11
',,/-i,
/
cr-i,
View from wire side
q
BI-U/BLX
22-