Memory Failure

System memory is full or a failure detected.
Applicable Error
03-600: Memory Failure
03-601: EPC Memory is Full
Initial Actions
Remove and re-seat memory DIMMs.
Increase system memory.
Delete unnecessary files or split the Fax job into smaller transmissions.
If problem persists use the following procedure.
Troubleshooting Reference Table
Applicable Parts
• Memory (Specifications).
• Main PWB: Phaser 3330 (PL 1.0.7,
List 1.0 Phaser 3330
3335 and 3345 (PL 6.1.7,
WorkCentre 3335/3345
Troubleshooting Procedure Table
Step
Actions and Questions
1.
Turn the machine off and then on.
Does the error persist?
2.
Re-seat memory DIMM on the Main PWB.
Does the error persist?
2-78
Phaser 3330 and WorkCentre 3335/3345
Service Manual
Wiring and Plug/Jack Map Reference
• Phaser 3330 Main PWB Connector Designators
Parts
• Phaser 3330 Control Panel PWB
Main), WorkCentre
• Wiring Diagrams for P3330/WC3335/WC3345
Parts List 6.1
• WorkCentre 3335/3345 Main PWB Connector Designators
Main).
Yes
Go to step 2.
Install a new Main PWB:
• Phaser 3330 (PL
1.0.7,
Parts List 1.0
Phaser 3330
Main)
• WorkCentre 3335 and
3345 (PL 6.1.7,
Parts
List 6.1 WorkCentre
3335/3345
Main).
No
Complete.