RMON configuration commands

display rmon alarm

Use display rmon alarm to display RMON alarm entries.
Syntax
display rmon alarm [ entry-number ] [ | { begin | exclude | include } regular-expression ]
Views
Any view
Default command level
1: Monitor level
Parameters
entry-number: Specifies the index of an RMON alarm entry, in the range of 1 to 65535. If no entry is
specified, the command displays all alarm entries.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Examples
# Display all RMON alarm entries.
<Sysname> display rmon alarm
AlarmEntry 1 owned by user1 is VALID.
Samples type
Variable formula
Sampling interval
Rising threshold
Falling threshold
When startup enables
Latest value
: absolute
: 1.3.6.1.2.1.16.1.1.1.4.1<etherStatsOctets.1>
: 10(sec)
: 50(linked with event 1)
: 5(linked with event 2)
: risingOrFallingAlarm
: 0
132