12 Troubleshooting and Maintenance

12-1 Actions for Problems

The following sections describe the preliminary checks and precautions that will be required if a
problem occurs.

12-1-1 Preliminary Checks When a Problem Occurs

This section explains the preliminary checks and analytical software required to determine the cause of
a problem if one occurs.
Checking the Power Supply Voltage
• Check the voltage at the power supply input terminals.
Main Circuit Power Supply Input Terminals (L1, L2, L3)
Model
R88D-KNL-ECT-L
R88D-KNH-ECT-L
R88D-KNF-ECT-L
Control Circuit Power Supply Input Terminals (L1C, L2C)
Model
R88D-KNL-ECT-L
R88D-KNH-ECT-L
R88D-KNF-ECT-L
If the voltage is out of range, there is a risk of operation failure. Be sure that the power supply is
within the specified range.
• Check the voltage of the sequence input power supply (+24 VIN terminal (CN1 pin 7)).
It must be between 11 and 25 VDC.
If the voltage is out of range, there is a risk of operation failure. Be sure that the power supply is within
the specified range.
Checking Whether an Error Has Occurred
Make an analysis using the 7-segment display on the front of the Servo Drive or using CX-Drive tools.
 When an Error Has Occurred
Check the error display () and make an analysis based on the error that is indicated.
 When an Error Has Not Occurred
Make an analysis according to the error conditions.
In either case, refer to 12-4 Troubleshooting on page 12-11 for details.
12-2
Capacity
100 W to 400 W
Single-phase 100 to 120 VAC (85 to 132 V) 50/60 Hz
100 W to 1.5 kW
Single-phase 200 to 240 VAC (170 to 264 V) 50/60 Hz
750 W to 1.5 kW
3-phase 200 to 240 VAC (170 to 264 V) 50/60 Hz
2 kW to 15 kW
3-phase 200 to 230 VAC (170 to 253 V) 50/60 Hz
750 W to 15 kW
3-phase 380 to 480 VAC (323 to 528 V) 50/60 Hz
Capacity
100 W to 400 W
Single-phase 100 to 120 VAC (85 to 132 V) 50/60 Hz
100 W to 1.5 kW
Single-phase 200 to 240 VAC (170 to 264 V) 50/60 Hz
2 kW to 15 kW
3-phase 200 to 230 VAC (170 to 253 V) 50/60 Hz
750 W to 15 kW
24 VDC (21.6 to 26.4 V)
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Power supply voltage
Power supply voltage