4 System Design
• Use a ground plate for the frame ground for each unit, as shown in the above diagrams, and ground
to a single point.
• Use ground lines with a minimum thickness of 3.5 mm
lines are as short as possible.
• A no-fuse breaker, surge absorber, and noise filter should be positioned near the input terminal block
(ground plate), and I/O lines should be separated and wired at the shortest distance.
Unit Details
Symbol
SG
Surge absorber
NF
Noise filter
SD
Servo Drive
LM
Linear Motor
FC1
Clamp core
FC2
Clamp core
FC3
Clamp core
TB
Switch box
-
Controller
*1 A specified combination of Servo Drive and Linear Motor must be used.
4-32
Name
Manufacturer
Okaya Electric
Industries Co., Ltd.
Okaya Electric
Industries Co., Ltd.
OMRON
TDK
Schaffner
NEC TOKIN
Corporation
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
2
, and arrange the wiring so that the ground
Model
·
·
Single-phase 100 VAC
R
A
V-781BWZ-4
·
·
3-phase 200 VAC
R
A
V-781BXZ-4
SUP-EK5-ER-6
Single-phase 100/200 VAC (5 A)
3SUP-HU10-ER-6
3-phase 200 VAC (10 A)
3SUP-HU30-ER-6
3-phase 200 VAC (30 A)
3SUP-HL50-ER-6B
3-phase 200 VAC (50 A)
ZCAT3035-1330
RJ8035
ESD-SR-250
Comment
*1
*1