9 Servo Parameter Objects
Warning Output Selection 1
3440 hex
Setting range
0 to 13
Size
2 bytes (INT16)
• Select the warning type to be output by Warning Output 1.
Explanation of Settings
Set value
0
Output by all types of warnings
1
Overload warning
2
Excessive regeneration warning
3
Reserved (Do not use.)
4
Fan warning
5
Reserved (Do not use.)
6
Reserved (Do not use.)
7
Vibration warning
8
Service life warning
9
External encoder error warning
10
External encoder communications error warning
11
Data setting warning
12
Command warning
13
EtherCAT communications warning
Refer to 12-2 Warnings on page 12-4.
Warning Output Selection 2
3441 hex
Setting range
0 to 13
Size
2 bytes (INT16)
• Select the warning type to be output by Warning Output 2.
• Refer to the Warning Output Selection 1 (3440 hex) for the object setting method.
Refer to 12-2 Warnings on page 12-4.
Positioning Completion Range 2
3442 hex
Setting range
0 to 262144
Size
4 bytes (INT32)
• Set the positioning completion range to output Positioning Completion Output 2 (INP2).
• The Positioning Completion Output 2 (INP2) is not affected by the position commands. It is ON as
long as the position error is below the set value.
The setting unit is command units. It can be changed to external encoder units by the Position Setting Unit
Selection (3520 hex).
as well.
9-36
Unit
Access
Unit
Access
Unit
Command unit Default setting
Access
However, note that the unit for the Following error window (6065 hex) will change
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Default setting
0
RW
PDO map
Description
Default setting
0
RW
PDO map
10
RW
PDO map
All
Data attribute
A
Not possible.
All
Data attribute
A
Not possible.
csp pp hm
Data attribute
A
Not possible.