Omron R88D-KN series User Manual page 535

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

Event name
Interface Input Function Number Error 2
Meaning
There is an undefined number specification in the input signal (IN5, IN6, IN7, and IN8) function allocations. Or, a logic
setting error was detected.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
There is an undefined number
specification in the input signal (IN5,
IN6, IN7, and IN8) function
allocations.
Different logic is set for the same
function in the function assignments
of the input signals (IN5, IN6, IN7,
and IN8).
Attached
None
information
Precautions/
"33" is displayed on the Servo Drive front panel and F333 is given as the AlarmCode (4001 hex).
Remarks
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Source details
Minor fault
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Allocate the functions to the
connector pins using only the
numbers that are defined.
Correct the settings so that the same
logic is used for the same function.
Event code
38480000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Allocate the functions to the
connector pins using only the
numbers that are defined.
Use the same logic for the same
function.
Appendicies
When
establishing
communications
after turning ON
power to the
slave or when
transferring
EtherCAT
Configuration
Setup
System
A-135

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents