9 Servo Parameter Objects
Notch 2 Frequency Setting
3204 hex
Setting range
50 to 5000
Size
2 bytes (INT16)
• Set the frequency of resonance suppression notch filter 2.
• The notch filter function is disabled if this object is set to 5000.
Refer to 11-7 Notch Filters on page 11-23.
Notch 2 Width Setting
3205 hex
Setting range
0 to 20
Size
2 bytes (INT16)
• Set the width of resonance suppression notch filter 2 to one of 20 levels.
• Increasing the setting value widens the notch width. Normally, use the default set value.
Refer to 11-7 Notch Filters on page 11-23.
Notch 2 Depth Setting
3206 hex
Setting range
0 to 99
Size
2 bytes (INT16)
• Set the depth of resonance suppression notch filter 2.
• Increasing the setting value shortens the notch depth and the phase lag.
Refer to 11-7 Notch Filters on page 11-23.
Notch 3 Frequency Setting
3207 hex
Setting range
50 to 5000
Size
2 bytes (INT16)
• Set the frequency of resonance suppression notch filter 3.
• The notch filter function is disabled if this object is set to 5000.
• While the adaptive filter is enabled, the resonance frequency 1 that is assumed by the adaptive filter
is automatically set. If no resonance point is found, the value 5000 is set.
Refer to 11-6 Adaptive Filter on page 11-20 and 11-7 Notch Filters on page 11-23.
Notch 3 Width Setting
3208 hex
Setting range
0 to 20
Size
2 bytes (INT16)
• Set the width of resonance suppression notch filter 3 to one of 20 levels.
• Increasing the setting value widens the notch width. Normally, use the default set value.
• While the adaptive filter is enabled, this object is set automatically.
Refer to 11-6 Adaptive Filter on page 11-20 and 11-7 Notch Filters on page 11-23.
9-18
Unit
Hz
Default setting
Access
Unit
Default setting
Access
Unit
Default setting
Access
Unit
Hz
Default setting
Access
Unit
Default setting
Access
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
5000
Data attribute
RW
PDO map
2
Data attribute
RW
PDO map
0
Data attribute
RW
PDO map
5000
Data attribute
RW
PDO map
2
Data attribute
RW
PDO map
All
B
Not possible.
All
B
Not possible.
All
B
Not possible.
All
B
Not possible.
All
B
Not possible.