Omron R88D-KN series User Manual page 536

G5-series with built-in ethercat communications linear motor type
Hide thumbs Also See for R88D-KN series:
Table of Contents

Advertisement

Appendicies
Event name
Interface Output Function Number Error 1
Meaning
There is an undefined number specification in the output signal (OUTM1) function allocation.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
There is an undefined number
specification in the output signal
(OUTM1) function allocation.
Attached
None
information
Precautions/
"33" is displayed on the Servo Drive front panel and F433 is given as the AlarmCode (4001 hex).
Remarks
Event name
Interface Output Function Number Error 2
Meaning
There is an undefined number specification in the output signal (OUTM2) function allocation.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherNet/IP NET RUN
---
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
There is an undefined number
specification in the output signal
(OUTM2) function allocation.
Attached
None
information
Precautions/
"33" is displayed on the Servo Drive front panel and F533 is given as the AlarmCode (4001 hex).
Remarks
A-136
Source details
Minor fault
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Allocate the functions to the
connector pins using only the
numbers that are defined.
Source details
Minor fault
Recovery
Continues.
Operation
EtherNet/IP NET ERR
---
Data type
---
Remedy
Allocate the functions to the
connector pins using only the
numbers that are defined.
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Event code
38490000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Allocate the functions to the
connector pins using only the
numbers that are defined.
Event code
384A0000 hex
Slave
Detection
timing
Error reset (after
Log category
cycling slave
power)
Power drive circuit is OFF for relevant slave.
EtherNet/IP LINK/ACT
---
Name
---
Prevention
Allocate the functions to the
connector pins using only the
numbers that are defined.
When
establishing
communications
after turning ON
power to the
slave or when
transferring
EtherCAT
Configuration
Setup
System
When
establishing
communications
after turning ON
power to the
slave or when
transferring
EtherCAT
Configuration
Setup
System

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents